LED T8 Retrofit Instructions
Green Ray LED T8 Lamps replace Fluorescent T8 – T12 lamps of the same length. Green Ray LED T8 lamps may be installed in fixtures holding T8 Fluorescent lamps by simply rewiring the fixture to bypass the Ballast. Green Ray LED lamps work in fixtures with voltages ranging from 100-277 V.
Lamp Replacement Compliance
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING - Risk of fire or electric shock. The electrical rating of these products are 100-277 Vac, the installer must determine whether they have 100-277 V at the luminare before installation.
WARNING – Risk of fire or electric shock. Reflector kit installation requires knowledge of fluorescent lighting luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
WARNING - Risk of fire or electric shock. Install these kits only in UL Listed or CSA Certified luminaires that have the construction features and dimensions shown in the photographs and/or drawings.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
The end retrofit luminaire has been modified and can no longer operate the originally intended lamp.
WARNING: Risk of fire or shock. Do not use this retrofit kit in luminaires employing shunted bi-pin lampholders.
Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS.
THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT AS A FLUORESCENT LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION
- The retrofit kit is suitable to be installed in an IC recessed ceiling mounted luminaire enclosed with a diffuser having a maximum of 4 LED tube lights.
- The retrofit kit is not suitable to be used with emergency exit luminaires.
- For more information, contact the LED luminaire retrofit kit manufacturer.
Clean up of broken Fluorescent Lamps ![]()
Disposing of Fluorescent Lamps ![]()
Step by Step Instructions:
Retrofit your existing T8 fixtures in just minutes.
Ready? Lets get started…